    Instructions for Use and Maintenance of the Sterilizer

    Release time:2015-09-07

    1. To ensure safe use, it is necessary to ensure Sterilizer The power cord has proper grounding.

    2. The sterilizer shall be placed in a suitable environment that is well-ventilated, dry, and free of flammable or explosive materials.

    3. Do not remove the lead seals or screws from the safety valve and steam vent.

    4. The items stacked inside the sterilizer must not exceed 80% of its capacity; otherwise, safety hazards may arise.

    5. Once the sealing ring becomes coated with oil, its elastomeric material is highly susceptible to damage, leading to air leakage; this should be strictly avoided.

    6. Chemical substances that may explode or experience a sudden pressure rise upon contact with steam shall not be sterilized using an autoclave.

    7. When stacking sterilized items, sufficient space must be left to ensure that the air vents of safety valves and steam-release valves are not blocked, thereby maintaining unobstructed airflow and ensuring safety.

    8. Liquids should be filled into heat-resistant glass bottles for sterilization; the liquid level should not exceed three-quarters of the bottle’s volume. The bottle opening should not be sealed with perforated rubber or cork stoppers, but rather with cotton-gauze plugs.

    9. Do not sterilize items of different types or with different sterilization requirements together.

    10. After sterilization is complete, do not release the steam immediately; wait until the pressure gauge pointer returns to zero before venting the remaining air.

    11. Pressure gauges shall be calibrated regularly and replaced promptly when necessary.

    12. Regularly inspect safety valves, and replace them immediately if they are found to be non-compliant.

    13. Regularly inspect the sealing integrity of the sealing rings and replace them promptly.

    14. After use, the water in the sterilizer’s chamber should be drained, and any scale buildup on the chamber or heating element should be removed to prolong the equipment’s service life.

    + More Products

    2025-05-19

    The 2025 Shanghai Pujiang International Intellectual Property Forum Concludes Successfully, with Jiangyin Binjiang Medical Equipment Co., Ltd.

    The 2025 Shanghai Pujiang International Intellectual Property Forum Concludes Successfully, with Jiangyin Binjiang Medical Equipment Co., Ltd.

    Learn More →

    2021-06-09

    Solemn Statement

    Recently, Jiangyin Binjiang Medical Equipment Co., Ltd. (hereinafter referred to as “our company”) discovered that information about our products and promotional materials are being posted on Taobao and various other online platforms. We hereby solemnly declare that, apart from our official website, our company has never registered any merchant accounts on any other online platforms, nor has it ever published product information or promotional materials on such platforms.

    Learn More →

    2020-11-25

    How to Properly Use Electric Heating Equipment Such as Oven Dryers

    The oven must be placed indoors in a dry, level location to prevent vibration and corrosion. Always ensure that the power supply is properly monitored: select a power switch and wiring that match the oven’s power consumption and capacity, and provide a reliable grounding connection.

    Learn More →

    2020-11-16

    Precautions for Steam Sterilizers

    Learn More →

    图片名称

    Empowering Healthcare Providers Worldwide


    Tel:+86-510-86270699       +86-510-86296768


    Add:No 38, Yungu Road, Changshou Community, Zhouzhuang Town, Jiangyin City, Jiangsu Province


    Copyright Jiangyin Binjiang Medical Equipment Co., Ltd. All Rights Reserved.