    1. Add water until the electric heating element is covered (approximately 3 liters). If the appliance is used continuously, the water level must be replenished as needed.
      2. Sealing: Place the items to be sealed evenly and in an orderly, staggered arrangement inside the drum, then place the drum into the chamber and secure the top cover. Insert the steam vent hose into the drum’s semicircular groove. After aligning the upper and lower grooves, tighten the wing nuts symmetrically until a tight seal is achieved (if air leakage occurs during use, simply continue tightening the nuts to eliminate it).
      3. Heating: After power is applied, first set the vent valve lever to the vertical vent position to allow cold air to escape from the chamber. Once steam begins to discharge, return the vent valve lever to its original position. When the pressure reaches the desired range, start timing according to the specific requirements for each item.
      4. Drying: After sterilization, if instruments, dressings, glassware, and other items need to be dried, fully vent the steam from the chamber by opening the steam release valve at the end of the sterilization cycle. Allow the pressure gauge to return to zero for 1–2 minutes, then open the lid and continue heating for an additional 10 minutes to achieve complete drying.
      Precautions:
      1. Before each disinfection, check the water level to prevent the heating element from overheating and damaging the cup.
      2. Different items should be disinfected separately.
      3. Regularly inspect the pressure gauge; if the pointer fails to return to zero or the readings are inaccurate, immediately shut off the heat source and have the gauge repaired or replaced without delay.
      4. During operation of the sterilizer, personnel must remain on site.

    + More Products

    2025-05-19

    The 2025 Shanghai Pujiang International Intellectual Property Forum Concludes Successfully, with Jiangyin Binjiang Medical Equipment Co., Ltd.

    The 2025 Shanghai Pujiang International Intellectual Property Forum Concludes Successfully, with Jiangyin Binjiang Medical Equipment Co., Ltd.

    Learn More →

    2021-06-09

    Solemn Statement

    Recently, Jiangyin Binjiang Medical Equipment Co., Ltd. (hereinafter referred to as “our company”) discovered that information about our products and promotional materials are being posted on Taobao and various other online platforms. We hereby solemnly declare that, apart from our official website, our company has never registered any merchant accounts on any other online platforms, nor has it ever published product information or promotional materials on such platforms.

    Learn More →

    2020-11-25

    How to Properly Use Electric Heating Equipment Such as Oven Dryers

    The oven must be placed indoors in a dry, level location to prevent vibration and corrosion. Always ensure that the power supply is properly monitored: select a power switch and wiring that match the oven’s power consumption and capacity, and provide a reliable grounding connection.

    Learn More →

    2020-11-16

    Precautions for Steam Sterilizers

    Learn More →

    图片名称

    Empowering Healthcare Providers Worldwide


    Tel:+86-510-86270699       +86-510-86296768


    Add:No 38, Yungu Road, Changshou Community, Zhouzhuang Town, Jiangyin City, Jiangsu Province


    Copyright Jiangyin Binjiang Medical Equipment Co., Ltd. All Rights Reserved.